EVALUATION OF AIR POLLUTANTS CONCENTRATION IN THE INDOOR SPACES OF PRINTING PRESSES IN ZARIA METROPOLIS
1 Department of Building, Ahmadu Bello University, Zaria, Kaduna State, Nigeria
2 Department of Quantity Surveying, Ahmadu Bello University, Zaria, Kaduna State, Nigeria
* Corresponding author: gbengabuilds@gmail.com
2 Department of Quantity Surveying, Ahmadu Bello University, Zaria, Kaduna State, Nigeria
* Corresponding author: gbengabuilds@gmail.com
Abstract
Purpose: Indoor Air Quality (IAQ) is becoming an increasingly important building design
consideration due to the growth in occupants’ health and comfort problems attributed to indoor
air pollution (IAP). This study evaluated the concentration of indoor air pollutants in the built
spaces of printing presses within the Zaria metropolis with the view to improving the IAQ of
this built environment.
Design/methodology/approach: The study adopted the quantitative research method. Twenty
two (22) printing presses were studied during active periods of printing to identify air pollutants.
Concentration levels were measured and compared against the National Environmental
Standard and Regulatory Enforcement Agency (NESREA) standard for excellent IAQ.
Handheld Air quality meter, Carbon monoxide meter, and Ozone concentration meter were used
to measure the mean concentration levels of nine (9) IAQ indicators; Temperature, Relative
humidity, Carbon monoxide (CO), Carbon dioxide (CO2), Total volatile organic compound
(TVOC), Formaldehyde (HCHO), Particulate matter (PM2.5 and PM10), and Ozone (O3). Data
collected in this study were analysed using descriptive and inferential statistics.
Findings: The concentration of the air pollutants in the printing presses were in the range:
Temperature (25-67-33.67oC), RH (56.33-85.00%), CO (0.00-31.00ppm), CO2 (533.67
1425.33ppm), TVOCs (0.113-9.999mg/m3), HCHO (0.015-0.078mg/m3), PM2.5 (21.33
426µg/m3), PM10, (28.00-568µg/m3), and O3 (0.00-0.05ppm). The mean concentration of
temperature, RH, TVOC, HCHO, PM2.5, and PM10 exceeded the acceptable threshold of the
NESREA standard in about 60% of the assessed presses.
Research limitations/Implications: Based on the air pollutant concentration levels recorded in
this study, printing press operators and users in the Zaria metropolis are at risk of developing
some health-related problems.
Practical implications: Regular IAQ assessment by press owners, inspection by regulatory
bodies, and installation of IAQ monitoring or capture systems are recommended to achieve good
IAQ levels as well as improve occupants’ wellbeing in the assessed printing presses.
Originality/value – The result of the study revealed the need to control the concentration of air
pollutants in the printing presses in the Zaria metropolis as the measured concentration of air
pollutants poses a major health threat to users of the facilities.
Keywords
Air Pollutant; Health; Indoor Air Quality (IAQ); NESREA standard; Printing press.
How to Cite
Ayeni, O., Ibrahim, E. C., Stanley, A. . M., Abdulsalam, D., Isah, I., Lawal, F. . M., & Agada, V. O. (2022). EVALUATION OF AIR POLLUTANTS CONCENTRATION IN THE INDOOR SPACES OF PRINTING PRESSES IN ZARIA METROPOLIS. Journal of Contemporary Research in the Built Environment, 6(1), 12-28. https://doi.org/10.68128/jocrebe.2022.vb4tje01
O. Ayeni, E. C. Ibrahim, A. . M. Stanley, D. Abdulsalam, I. Isah, F. . M. Lawal, and V. O. Agada, "EVALUATION OF AIR POLLUTANTS CONCENTRATION IN THE INDOOR SPACES OF PRINTING PRESSES IN ZARIA METROPOLIS," Journal of Contemporary Research in the Built Environment, vol. 6, no. 1, pp. 12-28, March 2022. doi: 10.68128/jocrebe.2022.vb4tje01